Hippe EP GM 201 Glass Mat Reinforced Epoxy Resin – Sheet
| Manufacturer | Erhard Hippe KG |
| Trade Name | |
| Port | Shanghai port,China |
| Trade Terms | FOB, CFR, CIF |
| Payment Terms | L/C, T/T, Western Union |
Category Epoxy, Molded, Glass Fiber Filler
Description
Material Notes:
Used in mechanical and electrical applications. Extremely high mechanical strength at moderate temperature. Very good electrical properties under high humidity.Information provided by Hippe.
| Physical Properties | Metric | English | Comments |
|---|---|---|---|
| Specific Gravity | 1.70 – 1.90 g/cc | 1.70 – 1.90 g/cc | IEC 1212-2 8.1 |
| Mechanical Properties | Metric | English | Comments |
|---|---|---|---|
| Tensile Strength | >= 250 MPa | >= 36300 psi | IEC 1212-2 5.7 |
| Flexural Strength | >= 320 MPa | >= 46400 psi | Perpendicular to laminations; IEC 1212-2 5.1 |
| Flexural Modulus | >= 15.0 GPa | >= 2180 ksi | IEC 1212-2 5.2 |
| Compressive Strength | >= 350 MPa | >= 50800 psi | Perpendicular to laminations; IEC 1212-2 5.3 |
| Shear Strength | >= 20.0 MPa | >= 2900 psi | Parallel to laminations; IEC 1212-2 5.6 |
| Izod Impact, Unnotched (ISO) | >= 54.0 kJ/m² | >= 25.7 ft-lb/in² | Parallel to laminations; IEC 1212-2 5.5.3 |
| Charpy Impact Unnotched | >= 5.00 J/cm² | >= 23.8 ft-lb/in² | Parallel to laminations; IEC 1212-2 5.5.2 |
| Electrical Properties | Metric | English | Comments |
|---|---|---|---|
| Insulation Resistance | >= 5.00e+9 ohm | >= 5.00e+9 ohm | After immersion in water; IEC 1212-2 6.3 |
| Dielectric Constant | <= 5.5
@Frequency 48.0 – 62.0 Hz
|
<= 5.5
@Frequency 48.0 – 62.0 Hz
|
IEC 1212-2 6.2 |
| <= 5.5
@Frequency 1.00e+6 Hz
|
<= 5.5
@Frequency 1.00e+6 Hz
|
IEC 1212-2 6.2 | |
| Dielectric Breakdown | >= 35000 V
@Temperature 90.0 °C
|
>= 35000 V
@Temperature 194 °F
|
In oil, parallel to laminations; IEC 1212-2 6.2 |
| Dissipation Factor | <= 0.050
@Frequency 48.0 – 62.0 Hz
|
<= 0.050
@Frequency 48.0 – 62.0 Hz
|
IEC 1212-2 6.2 |
| <= 0.050
@Frequency 1.00e+6 Hz
|
<= 0.050
@Frequency 1.00e+6 Hz
|
IEC 1212-2 6.2 | |
| Comparative Tracking Index | >= 200 V | >= 200 V | IEC 1212-2 6.4 |
| Descriptive Properties | Value | Comments |
|---|---|---|
| Thermal Endurance | 130 T.I. | IEC 1212-2 7.1 |
| Water Absorption | < 40 mg | IEC 1212-2 8.2; Test piece 50 x 50 x 10 mm |