Hippe MF GC 201 Woven Glass Cloth Reinforced Melamine Resin – Sheet

Manufacturer Erhard Hippe KG
Trade Name
Port Ningbo port,China
Trade Terms FOB, CFR, CIF
Payment Terms L/C, T/T, Western Union

Description

Material Notes:
Used in mechanical and electrical applications. High mechanical strength. Arc and tracking resistant. Flame retardant. Information provided by Hippe.
Physical Properties Metric English Comments
Specific Gravity 1.70 – 2.00 g/cc

1.70 – 2.00 g/cc

IEC 1212-2 8.1

 

Mechanical Properties Metric English Comments
Tensile Strength >= 150 MPa

>= 21800 psi

IEC 1212-2 5.7
Flexural Strength >= 240 MPa

>= 34800 psi

Perpendicular to laminations; IEC 1212-2 5.1
Flexural Modulus >= 14.0 GPa

>= 2030 ksi

IEC 1212-2 5.2
Compressive Strength >= 275 MPa

>= 39900 psi

Perpendicular to laminations; IEC 1212-2 5.3
Shear Strength >= 60.0 MPa

>= 8700 psi

Parallel to laminations; IEC 1212-2 5.6
Izod Impact, Unnotched (ISO) >= 31.0 kJ/m²

>= 14.8 ft-lb/in²

Parallel to laminations; IEC 1212-2 5.5.3
Charpy Impact Unnotched >= 3.00 J/cm²

>= 14.3 ft-lb/in²

Parallel to laminations; IEC 1212-2 5.5.2

 

Thermal Properties Metric English Comments
Flammability, UL94 V-0

V-0

IEC 1212-2 7.2

 

Electrical Properties Metric English Comments
Insulation Resistance >= 1.00e+8 ohm

>= 1.00e+8 ohm

After immersion in water; IEC 1212-2 6.3
Dielectric Constant <= 7.5

@Frequency 48.0 – 62.0 Hz
<= 7.5

@Frequency 48.0 – 62.0 Hz
IEC 1212-2 6.2
<= 7.5

@Frequency 1.00e+6 Hz
<= 7.5

@Frequency 1.00e+6 Hz
IEC 1212-2 6.2
Dielectric Breakdown >= 15000 V

@Temperature 90.0 °C
>= 15000 V

@Temperature 194 °F
In oil, parallel to laminations; IEC 1212-2 6.2
Dissipation Factor <= 0.020

@Frequency 48.0 – 62.0 Hz
<= 0.020

@Frequency 48.0 – 62.0 Hz
IEC 1212-2 6.2
<= 0.020

@Frequency 1.00e+6 Hz
<= 0.020

@Frequency 1.00e+6 Hz
IEC 1212-2 6.2
Comparative Tracking Index >= 500 V

>= 500 V

IEC 1212-2 6.4

 

Descriptive Properties Value Comments
Proof Tracking Index 500

IEC 1212-2 6.4
Thermal Endurance 130 T.I.

IEC 1212-2 7.1
Water Absorption < 414 mg

IEC 1212-2 8.2; Test piece 50 x 50 x 10 mm